sql

DCP-SOM-A/-AI - CLASS A SUPERVISED OUTPUT MODULE

CALL
Last Updated
15 Nov 2023
Minimum Order
1 1
Category
HOCHIKI

Specification of DCP-SOM-A/-AI - CLASS A SUPERVISED OUTPUT MODULE

 


DCP-SOM-A/-AI - CLASS A SUPERVISED OUTPUT MODULE


STANDARD FEATURES


 


 



  • Built-in SCI circuitry (SOM-AI only)

  • Flexible application

  • Quick response to emergency conditions

  • Operation parameters are maintained by the module, and individual communication with the control system during emergency conditions is not required

  • Contacts are rated 2.0 Amps @ 24VDC

  • Programming is highly flexible providing 16 priority states plus zoning capability

  • Programmed device output is turned off, silenced, or programmed to output the selected pattern

  • UL 864 Listed


 


DESCRIPTION


 


The Class A Supervised Output Modules (DCP-SOM-A & SOM-AI) have been designed to provide application flexibility and quick response to emergency conditions. Flexibility is provided by a wide range of operating modes, including supporting multi-zone operations, and/ or functions, up to 16 different modulation patterns and multi-state programming. The operating parameters for the DCP-SOM-A & -AI are maintained by the module and do not require individual communication with the control system during emergency conditions to operate. The control panel simply broadcasts system conditions on the Signaling Line Circuit (SLC) and the DCP-SOM-A



  1. -AI modules do the rest based upon the custom configuration. Each DCP-SOM-A & -AI provides a single Class B or Class A circuit rated for 2.0 Amps @ 24 VDC. Each DCP-SOM-A & -AI also requires a 24 VDC power source in addition to the SLC.


SPECIFICATIONS


 


























Supply Voltage (S-SC)



25.3 ~ 39 VDC



 



 



Auxiliary Supply Voltage



24 VDC



 



 



Average Current Consumption



 



 


SOM-AI - 420μA (Typical), SOM-A - 220μA (Typical) (on S-SC Line) Maximum 6mA: Red Alarm LED On




























































































Current Consumption on



 



 



Auxiliary Power Lines



 



Typical 50μA



SCI On Resistance



 



 



40m ohm Max. (Normal Condition)



 



 



 



SCI Fault Detection Threshold



12 volts (Typical)



 



 



 



SCI Isolation Current



 



 



(Short Circuit Condition)



 



10mA (Typical)



 



 



 



Maximum Quantity Per Loop



127



Dimensions



4.2"W x 4.7"H x 1.4"D



 



 



 



Ambient Temperature



32°F (0°C) ~ 120°F (49°C)



 



 



 



Mounting



4" square electrical box



Maximum Output Current



2A@24VDC power limited



 



 



 



Relative Humidity



90% RH Non-condensing